Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 102
Filter
2.
Article in English | MEDLINE | ID: mdl-38509402

ABSTRACT

BACKGROUND: Roughly one in six patients receiving conventional transvenous pacemaker systems experience significant complications within 1 year of implant, mainly due to the transvenous lead and subcutaneous pocket. A new helix-fixation single-chamber ventricular leadless pacemaker (LP) system capable of pre-deployment exploratory electrical mapping is commercially available. Such an LP may mitigate complications while streamlining the implantation. In this study, the initial real-world implant experience of the helix-fixation LP was evaluated following its commercial release. METHODS: In patients indicated for single-chamber right ventricular pacing, helix-fixation Aveir VR LPs (Abbott, Abbott Park, IL) were implanted using the dedicated loading tool, introducer, and delivery catheter. Implant procedural characteristics, electrical parameters, and any 30-day procedure-related adverse events of consecutive implant attempts were retrospectively evaluated. RESULTS: A total of 167 patients with Class I indication for permanent pacing received implants in four North American centers (57% male, 70 years old). Pre-fixation electrical mapping of potential sites allowed repositioning to be avoided in 95.7% of patients. Median [interquartile range] LP procedure and fluoroscopy durations were 25.5 min [20.0, 35.0] and 5.7 min [4.0, 9.2], respectively. Pacing capture threshold, sensed R-wave amplitude, and impedance were 0.8 V [0.5, 1.3], 9.0 mV [6.0, 12.0], and 705 Ω [550, 910], respectively. Implantation was successful in 98.8% of patients, with 98.2% free from acute adverse events. CONCLUSIONS: The initial, real-world experience of the helix-fixation ventricular leadless pacemaker demonstrated safe and efficient implantation with minimal repositioning, viable electrical metrics, and limited acute complications.

3.
JACC Cardiovasc Imaging ; 17(4): 411-424, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38300202

ABSTRACT

BACKGROUND: Imaging with late gadolinium enhancement (LGE) magnetic resonance (MR) and 18F-fluorodeoxyglucose (18F-FDG) PET allows complementary assessment of myocardial injury and disease activity and has shown promise for improved characterization of active cardiac sarcoidosis (CS) based on the combined positive imaging outcome, MR(+)PET(+). OBJECTIVES: This study aims to evaluate qualitative and quantitative assessments of hybrid MR/PET imaging in CS and to evaluate its association with cardiac-related outcomes. METHODS: A total of 148 patients with suspected CS underwent hybrid MR/PET imaging. Patients were classified based on the presence/absence of LGE (MR+/MR-), presence/absence of 18F-FDG (PET+/PET-), and pattern of 18F-FDG uptake (focal/diffuse) into the following categories: MR(+)PET(+)FOCAL, MR(+)PET(+)DIFFUSE, MR(+)PET(-), MR(-)PET(+)FOCAL, MR(-)PET(+)DIFFUSE, MR(-)PET(-). Further analysis classified MR positivity based on %LGE exceeding 5.7% as MR(+/-)5.7%. Quantitative values of standard uptake value, target-to-background ratio, target-to-normal-myocardium ratio (TNMRmax), and T2 were measured. The primary clinical endpoint was met by the occurrence of cardiac arrest, ventricular tachycardia, or secondary prevention implantable cardioverter-defibrillator (ICD) before the end of the study. The secondary endpoint was met by any of the primary endpoint criteria plus heart failure or heart block. MR/PET imaging results were compared between those meeting or not meeting the clinical endpoints. RESULTS: Patients designated MR(+)5.7%PET(+)FOCAL had increased odds of meeting the primary clinical endpoint compared to those with all other imaging classifications (unadjusted OR: 9.2 [95% CI: 3.0-28.7]; P = 0.0001), which was higher than the odds based on MR or PET alone. TNMRmax achieved an area under the receiver-operating characteristic curve of 0.90 for separating MR(+)PET(+)FOCAL from non-MR(+)PET(+)FOCAL, and 0.77 for separating those reaching the clinical endpoint from those not reaching the clinical endpoint. CONCLUSIONS: Hybrid MR/PET image-based classification of CS was statistically associated with clinical outcomes in CS. TNMRmax had modest sensitivity and specificity for quantifying the imaging-based classification MR(+)PET(+)FOCAL and was associated with outcomes. Use of combined MR and PET image-based classification may have use in prognostication and treatment management in CS.


Subject(s)
Cardiomyopathies , Myocarditis , Sarcoidosis , Humans , Fluorodeoxyglucose F18 , Cardiomyopathies/diagnostic imaging , Cardiomyopathies/therapy , Cardiomyopathies/complications , Contrast Media , Radiopharmaceuticals , Predictive Value of Tests , Gadolinium , Positron-Emission Tomography/methods , Magnetic Resonance Imaging/methods , Myocarditis/complications , Magnetic Resonance Spectroscopy , Sarcoidosis/diagnostic imaging , Sarcoidosis/therapy , Sarcoidosis/complications
4.
Heart Rhythm ; 2024 Feb 08.
Article in English | MEDLINE | ID: mdl-38336193

ABSTRACT

BACKGROUND: The PRAETORIAN score estimates the risk of failure of subcutaneous implantable cardioverter-defibrillator (S-ICD) therapy by using generator and lead positioning on bidirectional chest radiographs. The PRospective randomized compArative trial of subcutanEous implanTable cardiOverter-defibrillatoR ImplANtation with and without DeFibrillation Testing (PRAETORIAN-DFT) investigates whether PRAETORIAN score calculation is noninferior to defibrillation testing (DFT) with regard to first shock efficacy in spontaneous events. OBJECTIVE: This prespecified subanalysis assessed the predictive value of the PRAETORIAN score for defibrillation success in induced ventricular arrhythmias. METHODS: This multicenter investigator-initiated trial randomized 965 patients between DFT and PRAETORIAN score calculation after de novo S-ICD implantation. Successful DFT was defined as conversion of induced ventricular arrhythmia in <5 seconds from shock delivery within 2 attempts. Bidirectional chest radiographs were obtained after implantation. The predictive value of the PRAETORIAN score for DFT success was calculated for patients in the DFT arm. RESULTS: In total, 482 patients were randomized to undergo DFT. Of these patients, 457 (95%) underwent DFT according to protocol, of whom 445 (97%) had successful DFT and 12 (3%) had failed DFT. A PRAETORIAN score of ≥90 had a positive predictive value of 25% for failed DFT, and a PRAETORIAN score of <90 had a negative predictive value of 99% for successful DFT. A PRAETORIAN score of ≥90 was the strongest independent predictor for failed DFT (odds ratio 33.77; confidence interval 6.13-279.95; P < .001). CONCLUSION: A PRAETORIAN score of <90 serves as a reliable indicator for DFT success in patients with S-ICD, and a PRAETORIAN score of ≥90 is a strong predictor for DFT failure.

5.
JACC Clin Electrophysiol ; 9(8 Pt 2): 1437-1451, 2023 08.
Article in English | MEDLINE | ID: mdl-37480862

ABSTRACT

BACKGROUND: Premature ventricular complexes (PVCs) are prevalent and, although often benign, they may lead to PVC-induced cardiomyopathy. We created a deep-learning algorithm to predict left ventricular ejection fraction (LVEF) reduction in patients with PVCs from a 12-lead electrocardiogram (ECG). OBJECTIVES: This study aims to assess a deep-learning model to predict cardiomyopathy among patients with PVCs. METHODS: We used electronic medical records from 5 hospitals and identified ECGs from adults with documented PVCs. Internal training and testing were performed at one hospital. External validation was performed with the others. The primary outcome was first diagnosis of LVEF ≤40% within 6 months. The dataset included 383,514 ECGs, of which 14,241 remained for analysis. We analyzed area under the receiver operating curves and explainability plots for representative patients, algorithm prediction, PVC burden, and demographics in a multivariable Cox model to assess independent predictors for cardiomyopathy. RESULTS: Among the 14,241-patient cohort (age 67.6 ± 14.8 years; female 43.8%; White 29.5%, Black 8.6%, Hispanic 6.5%, Asian 2.2%), 22.9% experienced reductions in LVEF to ≤40% within 6 months. The model predicted reductions in LVEF to ≤40% with area under the receiver operating curve of 0.79 (95% CI: 0.77-0.81). The gradient weighted class activation map explainability framework highlighted the sinus rhythm QRS complex-ST segment. In patients who underwent successful PVC ablation there was a post-ablation improvement in LVEF with resolution of cardiomyopathy in most (89%) patients. CONCLUSIONS: Deep-learning on the 12-lead ECG alone can accurately predict new-onset cardiomyopathy in patients with PVCs independent of PVC burden. Model prediction performed well across sex and race, relying on the QRS complex/ST-segment in sinus rhythm, not PVC morphology.


Subject(s)
Cardiomyopathies , Deep Learning , Ventricular Premature Complexes , Adult , Humans , Female , Middle Aged , Aged , Aged, 80 and over , Stroke Volume , Ventricular Function, Left , Ventricular Premature Complexes/diagnosis , Ventricular Premature Complexes/surgery , Algorithms , Cardiomyopathies/complications , Cardiomyopathies/diagnosis , Electrocardiography
6.
JACC Clin Electrophysiol ; 9(8 Pt 3): 1804-1815, 2023 08.
Article in English | MEDLINE | ID: mdl-37354170

ABSTRACT

BACKGROUND: Interatrial block (IAB) is associated with thromboembolism and atrial arrhythmias. However, prior studies included small patient cohorts so it remains unclear whether IAB predicts adverse outcomes particularly in context of atrial fibrillation (AF)/atrial flutter (AFL). OBJECTIVES: This study sought to determine whether IAB portends increased stroke risk in a large cohort in the presence or absence of AFAF/AFL. METHODS: We performed a 5-center retrospective analysis of 4,837,989 electrocardiograms (ECGs) from 1,228,291 patients. IAB was defined as P-wave duration ≥120 ms in leads II, III, or aVF. Measurements were extracted as .XML files. After excluding patients with prior AF/AFL, 1,825,958 ECGs from 458,994 patients remained. Outcomes were analyzed using restricted mean survival time analysis and restricted mean time lost. RESULTS: There were 86,317 patients with IAB and 355,032 patients without IAB. IAB prevalence in the cohort was 19.6% and was most common in Black (26.1%), White (20.9%), and Hispanic (18.5%) patients and least prevalent in Native Americans (9.2%). IAB was independently associated with increased stroke probability (restricted mean time lost ratio coefficient [RMTLRC]: 1.43; 95% CI: 1.35-1.51; tau = 1,895), mortality (RMTLRC: 1.14; 95% CI: 1.07-1.21; tau = 1,924), heart failure (RMTLRC: 1.94; 95% CI: 1.83-2.04; tau = 1,921), systemic thromboembolism (RMTLRC: 1.62; 95% CI: 1.53-1.71; tau = 1,897), and incident AF/AFL (RMTLRC: 1.16; 95% CI: 1.10-1.22; tau = 1,888). IAB was not associated with stroke in patients with pre-existing AF/AFL. CONCLUSIONS: IAB is independently associated with stroke in patients with no history of AF/AFL even after adjustment for incident AF/AFL and CHA2DS2-VASc score. Patients are at increased risk of stroke even when AF/AFL is not identified.


Subject(s)
Atrial Fibrillation , Atrial Flutter , Stroke , Thromboembolism , Humans , Atrial Fibrillation/complications , Atrial Fibrillation/epidemiology , Interatrial Block/complications , Interatrial Block/epidemiology , Retrospective Studies , Electrocardiography , Stroke/epidemiology , Stroke/etiology , Atrial Flutter/complications , Atrial Flutter/epidemiology , Thromboembolism/epidemiology , Thromboembolism/etiology
8.
JACC Clin Electrophysiol ; 9(8 Pt 3): 1709-1716, 2023 08.
Article in English | MEDLINE | ID: mdl-37227360

ABSTRACT

BACKGROUND: Sustained ventricular tachycardia and sudden cardiac death due to degenerative mitral valve prolapse (MVP) can occur in the absence of severe mitral regurgitation (MR). A significant percentage of patients with MVP-related sudden death do not have any evidence of replacement fibrosis, suggesting other unrecognized proarrhythmic factors may place these patients at risk. OBJECTIVES: This study aims to characterize myocardial fibrosis/inflammation and ventricular arrhythmia complexity in patients with MVP and only mild or moderate MR. METHODS: Prospective observational study of patients with MVP and only mild or moderate MR underwent ventricular arrhythmia characterization and hybrid positron emission tomography (PET)/magnetic resonance imaging (MRI). Coregistered hybrid 18F-fluorodeoxyglucose (18F-FDG)-PET and MRI late gadolinium enhancement images were assessed and categorized. Recruitment occurred in the cardiac electrophysiology clinic. RESULTS: In 12 patients with degenerative MVP with only mild or moderate MR, of which a majority had complex ventricular ectopy (n = 10, 83%), focal (or focal-on-diffuse) uptake of 18F-FDG (PET-positive) was detected in 83% (n = 10) of patients. Three-quarters of the patients (n = 9, 75%) had FDG uptake that coexisted with areas of late gadolinium enhancement (PET/MRI-positive). Abnormal T1, T2 and extracellular volume (ECV) values were observed in 58% (n = 7), 25% (n = 3), and 16% (n = 2), respectively. CONCLUSIONS: Most patients with degenerative MVP, ventricular ectopy, and mild or moderate MR show myocardial inflammation that is concordant with myocardial scar. Further study is needed to determine whether these findings contribute to the observation that most MVP-related sudden deaths occur in patients with less than severe MR.


Subject(s)
Mitral Valve Insufficiency , Mitral Valve Prolapse , Ventricular Premature Complexes , Humans , Mitral Valve Prolapse/complications , Mitral Valve Prolapse/diagnostic imaging , Mitral Valve Prolapse/pathology , Mitral Valve Insufficiency/diagnostic imaging , Contrast Media , Gadolinium , Fluorodeoxyglucose F18 , Fibrosis , Inflammation
9.
JACC Case Rep ; 11: 101766, 2023 Apr 05.
Article in English | MEDLINE | ID: mdl-37077437

ABSTRACT

Supraventricular tachycardia with aberrancy and ventricular tachycardia can often be differentiated on the basis of subtle findings. We present an electrocardiogram with findings of Coumel's sign, which is diagnostic of atrioventricular re-entrant tachycardia using an accessory pathway. (Level of Difficulty: Advanced.).

10.
J Cardiovasc Electrophysiol ; 34(5): 1277-1285, 2023 05.
Article in English | MEDLINE | ID: mdl-36950852

ABSTRACT

INTRODUCTION: Multiple randomized controlled trials have demonstrated sodium-glucose cotransporter-2 inhibitors (SGLT2i) decrease the composite endpoint of cardiovascular death or heart failure hospitalizations in all heart failure patients. It is uncertain whether SGLT2i impacts the risk of sudden cardiac death in patients with heart failure. METHODS: A comprehensive search was performed to identify relevant data published before August 28, 2022. Trials were included if: (1) all patients had clinical heart failure (2) SGLT2i and placebo were compared (3) all patients received conventional medical therapy and (4) reported outcomes of interest (sudden cardiac death [SCD], ventricular arrhythmias, atrial arrhythmias). RESULTS: SCD was reported in seven of the eleven trials meeting selection criteria: 10 796 patients received SGLT2i and 10 796 received placebo. SGLT2i therapy was associated with a significant reduction in the risk of SCD (risk ratios [RR]: 0.68; 95% confidence intervals [CI]: 0.48-0.95; p = .03; I2 = 0%). Absent dedicated rhythm monitoring, there were no significant differences in the incidence of sustained ventricular arrhythmias not associated with SCD (RR: 1.03; 95% CI: 0.83-1.29; p = .77; I2 = 0%) or atrial arrhythmias (RR: 0.91; 95% CI: 0.77-1.09; p = .31; I2 = 29%) between patients receiving an SGLT2i versus placebo. CONCLUSION: SGLT2i therapy is associated with a reduced risk of SCD in patients with heart failure receiving contemporary medical therapy. Prospective trials are needed to determine the long-term impact of SGLT2i therapy on atrial and ventricular arrhythmias.


Subject(s)
Atrial Fibrillation , Heart Failure , Sodium-Glucose Transporter 2 Inhibitors , Humans , Atrial Fibrillation/complications , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Death, Sudden, Cardiac/epidemiology , Heart Failure/diagnosis , Heart Failure/drug therapy , Heart Failure/complications , Prospective Studies , Randomized Controlled Trials as Topic , Sodium-Glucose Transporter 2 Inhibitors/adverse effects
11.
JACC Clin Electrophysiol ; 9(4): 481-493, 2023 04.
Article in English | MEDLINE | ID: mdl-36752473

ABSTRACT

BACKGROUND: During atrial fibrillation ablations using thermal energy, the treatment effect is attributed to not just pulmonary vein isolation (PVI), but also to modulation of the autonomic nervous system by ablation of cardiac ganglionated plexi (GP). OBJECTIVES: This study sought to assess the impact of pulsed field ablation (PFA) on the GP in patients undergoing PVI. METHODS: In the retrospective phase, heart rate was assessed pre- versus post-PVI using PFA, cryoballoon ablation, or radiofrequency ablation. In the prospective phase, a pentaspline PFA catheter was used in a protocol: 1) pre-PFA, high-frequency stimulation (HFS) identified GP sites by vagal effects; 2) PVI was performed assessing for repetitive vagal effects over each set of PF applications; 3) mapping defined PVI extent to identify those GP in the ablation zone; and 4) repeat HFS at GP sites to assess for persistence of vagal effects. RESULTS: Between baseline and 3 months, heart rates in the retrospective radiofrequency ablation (n = 40), cryoballoon (n = 40), and PFA (n = 40) cohorts increased by 8.9 ± 11.4, 11.1 ± 9.4, and -0.1 ± 9.2 beats/min, respectively (P= 0.01 PFA vs radiofrequency ablation; P= 0.01 PFA vs cryoballoon ablation). In the prospective phase, pre-PFA HFS in 20 additional patients identified 65 GP sites. During PFA, vagal effects were noted in 45% of first PF applications, persisting through all applications in 83%. HFS post-PFA reproduced vagal effects in 29 of 38 sites (76%) in low-voltage tissue. CONCLUSIONS: PFA has minimal effect on GP. Unlike with thermal ablation, the mechanism by which PFA treats atrial fibrillation is mediated solely by durable PVI.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Humans , Retrospective Studies , Prospective Studies , Catheter Ablation/adverse effects , Vagus Nerve/surgery
12.
J Am Coll Cardiol ; 80(24): 2331-2347, 2022 12 13.
Article in English | MEDLINE | ID: mdl-36480975

ABSTRACT

In light of the adverse prognosis related to severe mitral regurgitation, heart failure, or sudden cardiac death in a subset of patients with mitral valve prolapse (MVP), identifying those at higher risk is key. For the first time in decades, researchers have the means to rapidly advance discovery in the field of MVP thanks to state-of-the-art imaging techniques, novel omics methodologies, and the potential for large-scale collaborations using web-based platforms. The National Heart, Lung, and Blood Institute recently initiated a webinar-based workshop to identify contemporary research opportunities in the treatment of MVP. This report summarizes 3 specific areas in the treatment of MVP that were the focus of the workshop: 1) improving management of degenerative mitral regurgitation and associated left ventricular systolic dysfunction; 2) preventing sudden cardiac death in MVP; and 3) understanding the mechanisms and progression of MVP through genetic studies and small and large animal models, with the potential of developing medical therapies.


Subject(s)
Mitral Valve Prolapse , Humans , Death, Sudden, Cardiac
14.
Heart Rhythm ; 19(12): 1993-2001, 2022 12.
Article in English | MEDLINE | ID: mdl-35944889

ABSTRACT

BACKGROUND: Early subcutaneous implantable cardioverter-defibrillator (S-ICD) studies included atypical cohorts of patients who were younger with fewer comorbidities. Recent S-ICD studies included patient populations with more comorbidities. OBJECTIVES: The goals of this study were to determine the incidence and predictors of S-ICD-related infection over a 3-year follow-up period and to use these results to develop an infection risk score. METHODS: The S-ICD Post Approval Study is a US prospective registry of 1637 patients. Baseline demographic characteristics and outcomes with 3-year postimplantation follow-up were compared between patients with and without device-related infection. A risk score was derived from multivariable proportional hazards analysis of 22 variables. RESULTS: Infection was observed in 55 patients (3.3%), with 69% of infections occurring within 90 days and a vast majority (92.7%) within 1 year of implantation. Late infections more likely involved device erosion; no infections occurred after year 2. The annual mortality rate postinfection was 0.6%/y. No lead extraction complications or bacteremia related to infection were observed. An infection risk score was created with diabetes, age, prior transvenous ICD implant, and ejection fraction as predictors. Patients with a risk score of ≥3 had an 8.8 hazard ratio (95% confidence interval 2.8-16.3) of infection compared with a 0 risk score. CONCLUSION: Infection rates in the S-ICD Post Approval Study were similar to other S-ICD populations and not associated with systemic blood-borne infections. Late infection (>1 year) is uncommon and associated with system erosion. A high-risk infection cohort can be identified that may facilitate preventive measures.


Subject(s)
Defibrillators, Implantable , Humans , Defibrillators, Implantable/adverse effects , Treatment Outcome , Prosthesis Implantation/methods , Registries , Cohort Studies
15.
Eur Heart J ; 43(47): 4872-4883, 2022 12 14.
Article in English | MEDLINE | ID: mdl-36030464

ABSTRACT

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) is developed to overcome lead-related complications and systemic infections, inherent to transvenous ICD (TV-ICD) therapy. The PRAETORIAN trial demonstrated that the S-ICD is non-inferior to the TV-ICD with regard to the combined primary endpoint of inappropriate shocks and complications. This prespecified secondary analysis evaluates all complications in the PRAETORIAN trial. METHODS AND RESULTS: The PRAETORIAN trial is an international, multicentre, randomized trial in which 849 patients with an indication for ICD therapy were randomized to receive an S- ICD (N = 426) or TV-ICD (N = 423) and followed for a median of 49 months. Endpoints were device-related complications, lead-related complications, systemic infections, and the need for invasive interventions. Thirty-six device-related complications occurred in 31 patients in the S-ICD group of which bleedings were the most frequent. In the TV-ICD group, 49 complications occurred in 44 patients of which lead dysfunction was most frequent (HR: 0.69; P = 0.11). In both groups, half of all complications were within 30 days after implantation. Lead-related complications and systemic infections occurred significantly less in the S-ICD group compared with the TV-ICD group (P < 0.001, P = 0.03, respectively). Significantly more complications required invasive interventions in the TV-ICD group compared with the S-ICD group (8.3% vs. 4.3%, HR: 0.59; P = 0.047). CONCLUSION: This secondary analysis shows that lead-related complications and systemic infections are more prevalent in the TV-ICD group compared with the S-ICD group. In addition, complications in the TV-ICD group were more severe as they required significantly more invasive interventions. This data contributes to shared decision-making in clinical practice.


Subject(s)
Death, Sudden, Cardiac , Defibrillators, Implantable , Humans , Treatment Outcome , Defibrillators, Implantable/adverse effects
16.
J Cardiovasc Electrophysiol ; 33(7): 1628-1635, 2022 07.
Article in English | MEDLINE | ID: mdl-35662315

ABSTRACT

BACKGROUND: Infection remains a major complication of cardiac implantable electronic devices and can lead to significant morbidity and mortality. Implantable devices that avoid transvenous leads, such as the subcutaneous implantable cardioverter-defibrillator (S-ICD), can reduce the risk of serious infection-related complications, such as bloodstream infection and infective endocarditis. While the 2017 AHA/ACC/HRS guidelines include recommendations for S-ICD use for patients at high risk of infection, currently, there are no clinical trial data that address best practices for the prevention of S-ICD infections. Therefore, an expert panel was convened to develop a consensus on these topics. METHODS: An expert process mapping methodology was used to achieve consensus on the appropriate steps to minimize or prevent S-ICD infections. Two face-to-face meetings of high-volume S-ICD implanters and an infectious diseases specialist, with expertise in cardiovascular implantable electronic device infections, were conducted to develop consensus on useful strategies pre-, peri-, and postimplant to reduce S-ICD infection risk. RESULTS: Expert panel consensus on recommended steps for patient preparation, S-ICD implantation, and postoperative management was developed to provide guidance in individual patient management. CONCLUSION: Achieving expert panel consensus by process mapping methodology for S-ICD infection prevention was attainable, and the results should be helpful to clinicians in adopting interventions to minimize risks of S-ICD infection.


Subject(s)
Defibrillators, Implantable , Consensus , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Defibrillators, Implantable/adverse effects , Humans , Treatment Outcome
19.
J Am Coll Cardiol ; 79(12): 1199-1211, 2022 03 29.
Article in English | MEDLINE | ID: mdl-35331415

ABSTRACT

Interatrial block (IAB) is an electrocardiographic pattern describing the conduction delay between the right and left atria. IAB is classified into 3 degrees of block that correspond to decreasing conduction in the region of Bachmann's bundle. Although initially considered benign in nature, specific subsets of IAB have been associated with atrial arrhythmias, elevated thromboembolic stroke risk, cognitive impairment, and mortality. As the pathophysiologic relationships between IAB and stroke are reinforced, investigation has now turned to the potential benefit of early detection, atrial imaging, cardiovascular risk factor modification, antiarrhythmic pharmacotherapy, and stroke prevention with oral anticoagulation. This review provides a contemporary overview of the epidemiology, pathophysiology, diagnosis, and management of IAB, with a focus on future directions.


Subject(s)
Atrial Fibrillation , Stroke , Atrial Fibrillation/complications , Electrocardiography/methods , Heart Atria/diagnostic imaging , Heart Block/diagnosis , Heart Block/epidemiology , Heart Block/etiology , Humans , Interatrial Block/complications , Interatrial Block/diagnosis , Interatrial Block/epidemiology , Stroke/epidemiology , Stroke/etiology , Stroke/prevention & control
20.
J Cardiovasc Electrophysiol ; 33(4): 725-730, 2022 04.
Article in English | MEDLINE | ID: mdl-35066954

ABSTRACT

INTRODUCTION: Transvenous implantable cardioverter-defibrillators (TV-ICD) infection is a serious complication that frequently requires complete device removal for attempted cure, which can be associated with patient morbidity and mortality. The objective of this study is to assess mortality risk associated with TV-ICD infection in a large Medicare population with de novo TV-ICD implants. METHODS: A survival analysis was conducted using 100% fee-for-service Medicare facility-level claims data to identify patients who underwent de novo TV-ICD implantation between 7/2016 and 1/2018. TV-ICD infection within 2 years of implantation was identified using International Classification of Disease, 10th Edition and current procedural terminology codes. Baseline patient risk factors associated with mortality were identified using the Charlson Comorbidity Index categories. Infection was treated as a time-dependent variable in a multivariate Cox proportional hazards model to account for immortal time bias. RESULTS: Among 26,742 Medicare patients with de novo TV-ICD, 518 (1.9%) had a device-related infection. The overall number of decedents was 4721 (17.7%) over 2 years, with 4555 (17%) in the noninfection group and 166 (32%) in the infection group. After adjusting for baseline patient demographic characteristics and various comorbidities, the presence of TV-ICD infection was associated with an increase of 2.4 (95% CI: 2.08-2.85) times in the mortality hazard ratio. CONCLUSION: The rate of TV-ICD infection and associated mortality in a large, real-world Medicare population is noteworthy. The positive association between device-related infection and risk of mortality further highlights the need to reduce infections.


Subject(s)
Defibrillators, Implantable , Aged , Defibrillators, Implantable/adverse effects , Electric Countershock , Humans , Medicare , Prosthesis-Related Infections/epidemiology , Prosthesis-Related Infections/etiology , Prosthesis-Related Infections/mortality , Retrospective Studies , Treatment Outcome , United States/epidemiology
SELECTION OF CITATIONS
SEARCH DETAIL
...